modem manufacturer: SCADA applications for modem data communication modems Mexico, South and Central and Latin America AmericaSpanishChinese
Data-Linc modems, tech support, industry alliances, sales channels, trade shows, informationIndustriesHomeAbout usNewsSales ChannelsPartnerships/alliancesTechnical ServicesProducts
product indicatorList of Antennas and CablesNET620Ń Serial to Ethernet BridgeList of Wire modemsList of Wireless modems

Material handlinghydro-electric powerOil rig drillinggas pipelineminingforestry logging

SCADA & video data on one high-speed network minimize remote visits

solution for SCADA & video dataDATA-LINC’s SAA-V Security Engine “bundled solution” supports wireless video and SCADA on a single high-speed (54Mbps) network in the 900 MHz and 2.4 GHz bands. It not only offers security but also provides visual monitoring of your SCADA operation, allowing the operator to view and zoom in on a potential trouble spot, minimizing unnecessary trips to remote locations when a trigger event occurs. The SAA-V solution allows virtually limitless control via user selectable, external program execution with notification on-screen, by voice, on the phone or by email. It easily scales up to fit your video security and SCADA needs, seamlessly integrating with industry standard networks, servers, databases and storage systems. It also offers OPC connectivity. The advantage DATA-LINC offers over other systems is their expertise in industrial wireless communication, knowledge of the automation and security industry and bundled components for ease of installation. SAA-V provides coverage from process to perimeter backed by field-proven performance and industrial grade support.

Innovative, Not Your Standard I/O

Communication Interface I/O ExtenderData-Linc’s wireless “CIX” Communication Interface Extender System (900 MHz and 2.4 GHz versions) provides a cost effective, easy-to-implement, industrial grade I/O extender that directly connects a PLC’s communication ports (serial or Ethernet) to I/O points without complicated PLC programming or proprietary software. With a ratio of up to 16 Remotes for each Master, a full network provides a total of 384 I/O points. Each CIX6x00/R Remote provides 8 discrete inputs, 8 discrete outputs, four analog inputs and four analog outputs (12 bit analog resolution). It is compatible with LincView OPC, Data-Linc’s powerful, proprietary RF network diagnostic and management software. Read the press release and see the data sheet. For more information regarding how this or any of our other products can provide solutions for your industrial or instrumentation projects, call 425-882-2206 or email (for I/O projects not requiring serial or Ethernet interface, see "The DAX")

PLR580 I/O Extenders save thousands of dollars

Problem: A client needed to get three 4-20 ma signals and four digital inputs from a tank farm to their control room PLC, in order to read the level of the tanks. They also needed to send three analog and four digital output signals back to the tank farm to control tank levels. The distance from the control room to the pumping station was 4000 feet. To further complicate matters, 10 years earlier the customer had added a new facility with a parking lot that was constructed between the tank farm and the control room. Because they did not want to mix the analog and 120 volt signals in one conduit, they were considering trenching through the concrete parking lot to run cable tray or two underground conduits to the tank farm. Trenching would cost an estimate of between $13,000 and $15,000 for material and labor. Click here for the solution.

Hybrid is not just for cars

Data-Linc Ggroup introduces hybrid serial-Ethernet modems for Instrumentation and Industrial Automation environments. The 900 MHz SRM6220 and the 2.4 GHz SRM6320 modems feature Ethernet with serial tunneling that allows the user to connect to serial and/or Ethernet devices without requiring side by side networks or Ethernet-serial converters. Read the press release or get detailed information from the data sheets for the SRM6220 and the SRM6320.

Data-Linc Group now offers customers hybrid serial-Ethernet modems for Instrumentation and Industrial Automation environments. The 900 MHz SRM6220 and the 2.4 GHz SRM6320 modems feature Ethernet with serial tunneling that allows the user to connect to serial and/or Ethernet devices without requiring side by side networks or Ethernet-serial converters. Read the press release or get detailed information from the data sheets for the SRM6220 and the SRM6320.

Contact us via phone 425-882-2206 PCT or for more information about these and other robust industrial grade data communication products. All Data-Linc Group modems offer field proven performance and come with free industrial grade support.

Top of Page ^

Products

Features & Benefits | Focus Item | Product Selection Guides | Catalog | PDF Library | Order Information | FAQ
Tech Resources

Engineering Specifications | Articles & Technical Papers | Installation Information
Partners

GE Fanuc | Omron | Rockwell Automation | Schneider Electric | Siemens | Technology Partners
Industries

Security | and other industry application notes and diagrams
Sales Channels

Distributors | System Integrators | OEMs
News

Tradeshows and Events | Press Releases | Newsletters
About Us

Overview | Jobs/Employment | Office Locations/Contact Information

spacerChinesespacerEspañol

spacer
Data-Linc Group
3535 Factoria Blvd. SE, Suite 100 • Bellevue, WA 98006 USA
Tel (425) 882-2206 • Fax (425) 867-0865 •

© 1996-2011 Data-Linc Group. All rights reserved.
110609